Context of Issue
Context: Extension-UKCore-CodingSCTDescDisplay (Extension)
Type: Implementation Guide
Source: UK Core Development Team
Scope: Proposed In Scope

Issue Proposal
The IG guidance states that if the sct-descId is sent, then the UK Core sctdescDisplay SHALL be used. Initial Proposal:

The requirement should be changed from SHALL to MAY.

Click here

Main Points Raised in C&TA Calls:

Kevin Sprague:

  • There’s a live vendor issue suggesting UK Core diverges from base FHIR behavior; reviewing; may need options (including deprecation).
Ann Wrightson:
  • While under review, relaxing to MAY helps implementers and reduces harm.
Charlie McCay:
  • This should be solved internationally (HL7 + SNOMED), not by a UK only extension; avoid extending extensions; basic FHIR–SNOMED integration must be straightforward.
Ryan May:
  • Context: the need was to send a non preferred term text alongside the conceptId; past misuse included sending descriptionIds as codes.