This CodeSystem has may be new or has been amended since the last ballot. Users are advised to review all content carefully. Details of the changes can be found within the UK Core Version History.StructureDefinition UKCore-Device-BloodPressure
| Canonical_URL | Status | Current_Version | Last_Updated | Description |
|---|---|---|---|---|
| https://fhir.hl7.org.uk/StructureDefinition/UKCore-Device-BloodPressure | active | 1.0.1 | 2025-08-01 | Defines the additional constraints and extensions on the UK Core Device profile, for specific devices relating to the recording of blood pressures. |
| Profile_Purpose |
|---|
The purpose of this profile is to hold information about a device used to measure blood pressure, such as the type or sphygmomanometer, and cuff size used. |
Detailed Descriptions
| Device | |||
| Short | Item used in healthcare | ||
| Definition | A type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device. | ||
| Cardinality | 0..* | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.id | |||
| Short | Logical id of this artifact | ||
| Definition | The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Summary | True | ||
| Comments | The only time that a resource does not have an id is when it is being submitted to the server using a create operation. | ||
| Device.meta | |||
| Short | Metadata about the resource | ||
| Definition | The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource. | ||
| Cardinality | 0..1 | ||
| Type | Meta | ||
| Summary | True | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.implicitRules | |||
| Short | A set of rules under which this content was created | ||
| Definition | A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. | ||
| Cardinality | 0..1 | ||
| Type | uri | ||
| Modifier | True | ||
| Summary | True | ||
| Comments | Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.language | |||
| Short | Language of the resource content | ||
| Definition | The base language in which the resource is written. | ||
| Cardinality | 0..1 | ||
| Type | code | ||
| Binding | A human language.
| ||
| Comments | Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.text | |||
| Short | Text summary of the resource, for human interpretation | ||
| Definition | A human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. | ||
| Cardinality | 0..1 | ||
| Type | Narrative | ||
| Alias | narrative, html, xhtml, display | ||
| Comments | Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.contained | |||
| Short | Contained, inline Resources | ||
| Definition | These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. | ||
| Cardinality | 0..* | ||
| Type | Resource | ||
| Alias | inline resources, anonymous resources, contained resources | ||
| Comments | This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels. | ||
| Mappings |
| ||
| Device.extension | |||
| Short | Additional content defined by implementations | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Alias | extensions, user content | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.extension:cuffSize | |||
| Short | A code representing the cuff size of a sphygmomanometer. | ||
| Definition | This extension allows the recording of the cuff size of a sphygmomanometer used in a blood pressure reading. | ||
| Cardinality | 0..* | ||
| Type | Extension(CodeableConcept) | ||
| Alias | extensions, user content | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.modifierExtension | |||
| Short | Extensions that cannot be ignored | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Modifier | True | ||
| Alias | extensions, user content | ||
| Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.identifier | |||
| Short | Instance identifier | ||
| Definition | Unique instance identifiers assigned to a device by manufacturers other organizations or owners. | ||
| Cardinality | 0..* | ||
| Type | Identifier | ||
| Comments | The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.definition | |||
| Short | The reference to the definition for the device | ||
| Definition | The reference to the definition for the device. | ||
| Cardinality | 0..1 | ||
| Type | Reference(DeviceDefinition) | ||
| Comments | References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier | |||
| Short | Unique Device Identifier (UDI) Barcode string | ||
| Definition | Unique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold. | ||
| Cardinality | 0..* | ||
| Type | BackboneElement | ||
| Summary | True | ||
| Comments | UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.id | |||
| Short | Unique id for inter-element referencing | ||
| Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Mappings |
| ||
| Device.udiCarrier.extension | |||
| Short | Additional content defined by implementations | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Alias | extensions, user content | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.modifierExtension | |||
| Short | Extensions that cannot be ignored even if unrecognized | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Modifier | True | ||
| Summary | True | ||
| Alias | extensions, user content, modifiers | ||
| Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.deviceIdentifier | |||
| Short | Mandatory fixed portion of UDI | ||
| Definition | The device identifier (DI) is a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Summary | True | ||
| Alias | DI | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.issuer | |||
| Short | UDI Issuing Organization | ||
| Definition | Organization that is charged with issuing UDIs for devices. For example, the US FDA issuers include :
| ||
| Cardinality | 0..1 | ||
| Type | uri | ||
| Alias | Barcode System | ||
| Comments | see http://en.wikipedia.org/wiki/Uniform_resource_identifier | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.jurisdiction | |||
| Short | Regional UDI authority | ||
| Definition | The identity of the authoritative source for UDI generation within a jurisdiction. All UDIs are globally unique within a single namespace with the appropriate repository uri as the system. For example, UDIs of devices managed in the U.S. by the FDA, the value is http://hl7.org/fhir/NamingSystem/fda-udi. | ||
| Cardinality | 0..1 | ||
| Type | uri | ||
| Requirements | Allows a recipient of a UDI to know which database will contain the UDI-associated metadata. | ||
| Comments | see http://en.wikipedia.org/wiki/Uniform_resource_identifier | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.carrierAIDC | |||
| Short | UDI Machine Readable Barcode String | ||
| Definition | The full UDI carrier of the Automatic Identification and Data Capture (AIDC) technology representation of the barcode string as printed on the packaging of the device - e.g., a barcode or RFID. Because of limitations on character sets in XML and the need to round-trip JSON data through XML, AIDC Formats SHALL be base64 encoded. | ||
| Cardinality | 0..1 | ||
| Type | base64Binary | ||
| Summary | True | ||
| Alias | Automatic Identification and Data Capture | ||
| Comments | The AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.carrierHRF | |||
| Short | UDI Human Readable Barcode String | ||
| Definition | The full UDI carrier as the human readable form (HRF) representation of the barcode string as printed on the packaging of the device. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Summary | True | ||
| Alias | Human Readable Form | ||
| Comments | If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.udiCarrier.entryType | |||
| Short | barcode | rfid | manual + | ||
| Definition | A coded entry to indicate how the data was entered. | ||
| Cardinality | 0..1 | ||
| Type | code | ||
| Binding | Codes to identify how UDI data was entered. | ||
| Requirements | Supports a way to distinguish hand entered from machine read data. | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.status | |||
| Short | active | inactive | entered-in-error | unknown | ||
| Definition | Status of the Device availability. | ||
| Cardinality | 0..1 | ||
| Type | code | ||
| Binding | The availability status of the device. | ||
| Modifier | True | ||
| Summary | True | ||
| Comments | This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.statusReason | |||
| Short | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off | ||
| Definition | Reason for the dtatus of the Device availability. | ||
| Cardinality | 0..* | ||
| Type | CodeableConcept | ||
| Binding | The availability status reason of the device. | ||
| Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.distinctIdentifier | |||
| Short | The distinct identification string | ||
| Definition | The distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Alias | Distinct Identification Code (DIC) | ||
| Comments | For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c). | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.manufacturer | |||
| Short | Name of device manufacturer | ||
| Definition | A name of the manufacturer. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.manufactureDate | |||
| Short | Date when the device was made | ||
| Definition | The date and time when the device was manufactured. | ||
| Cardinality | 0..1 | ||
| Type | dateTime | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.expirationDate | |||
| Short | Date and time of expiry of this device (if applicable) | ||
| Definition | The date and time beyond which this device is no longer valid or should not be used (if applicable). | ||
| Cardinality | 0..1 | ||
| Type | dateTime | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.lotNumber | |||
| Short | Lot number of manufacture | ||
| Definition | Lot number assigned by the manufacturer. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.serialNumber | |||
| Short | Serial number assigned by the manufacturer | ||
| Definition | The serial number assigned by the organization when the device was manufactured. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Comments | Alphanumeric Maximum 20. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.deviceName | |||
| Short | The name of the device as given by the manufacturer | ||
| Definition | This represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition. | ||
| Cardinality | 0..* | ||
| Type | BackboneElement | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.deviceName.id | |||
| Short | Unique id for inter-element referencing | ||
| Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Mappings |
| ||
| Device.deviceName.extension | |||
| Short | Additional content defined by implementations | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Alias | extensions, user content | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.deviceName.modifierExtension | |||
| Short | Extensions that cannot be ignored even if unrecognized | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Modifier | True | ||
| Summary | True | ||
| Alias | extensions, user content, modifiers | ||
| Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.deviceName.name | |||
| Short | The name of the device | ||
| Definition | The name of the device. | ||
| Cardinality | 1..1 | ||
| Type | string | ||
| Alias | Σ | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.deviceName.type | |||
| Short | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other | ||
| Definition | The type of deviceName. UDILabelName | UserFriendlyName | PatientReportedName | ManufactureDeviceName | ModelName. | ||
| Cardinality | 1..1 | ||
| Type | code | ||
| Binding | The type of name the device is referred by. | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.modelNumber | |||
| Short | The model number for the device | ||
| Definition | The model number for the device. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.partNumber | |||
| Short | The part number of the device | ||
| Definition | The part number of the device. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Comments | Alphanumeric Maximum 20. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.type | |||
| Short | The kind or type of device | ||
| Definition | The kind or type of device. | ||
| Cardinality | 0..1 | ||
| Type | CodeableConcept | ||
| Binding | Codes to identify medical devices. https://fhir.hl7.org.uk/ValueSet/UKCore-BloodPressureDeviceType (preferred) | ||
| Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.specialization | |||
| Short | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | ||
| Definition | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication. | ||
| Cardinality | 0..* | ||
| Type | BackboneElement | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.specialization.id | |||
| Short | Unique id for inter-element referencing | ||
| Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Mappings |
| ||
| Device.specialization.extension | |||
| Short | Additional content defined by implementations | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Alias | extensions, user content | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.specialization.modifierExtension | |||
| Short | Extensions that cannot be ignored even if unrecognized | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Modifier | True | ||
| Summary | True | ||
| Alias | extensions, user content, modifiers | ||
| Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.specialization.systemType | |||
| Short | The standard that is used to operate and communicate | ||
| Definition | The standard that is used to operate and communicate. | ||
| Cardinality | 1..1 | ||
| Type | CodeableConcept | ||
| Alias | Σ | ||
| Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.specialization.version | |||
| Short | The version of the standard that is used to operate and communicate | ||
| Definition | The version of the standard that is used to operate and communicate. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.version | |||
| Short | The actual design of the device or software version running on the device | ||
| Definition | The actual design of the device or software version running on the device. | ||
| Cardinality | 0..* | ||
| Type | BackboneElement | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.version.id | |||
| Short | Unique id for inter-element referencing | ||
| Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Mappings |
| ||
| Device.version.extension | |||
| Short | Additional content defined by implementations | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Alias | extensions, user content | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.version.modifierExtension | |||
| Short | Extensions that cannot be ignored even if unrecognized | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Modifier | True | ||
| Summary | True | ||
| Alias | extensions, user content, modifiers | ||
| Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.version.type | |||
| Short | The type of the device version | ||
| Definition | The type of the device version. | ||
| Cardinality | 0..1 | ||
| Type | CodeableConcept | ||
| Alias | Σ | ||
| Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.version.component | |||
| Short | A single component of the device version | ||
| Definition | A single component of the device version. | ||
| Cardinality | 0..1 | ||
| Type | Identifier | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.version.value | |||
| Short | The version text | ||
| Definition | The version text. | ||
| Cardinality | 1..1 | ||
| Type | string | ||
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.property | |||
| Short | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | ||
| Definition | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties. | ||
| Cardinality | 0..* | ||
| Type | BackboneElement | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.property.id | |||
| Short | Unique id for inter-element referencing | ||
| Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | ||
| Cardinality | 0..1 | ||
| Type | string | ||
| Mappings |
| ||
| Device.property.extension | |||
| Short | Additional content defined by implementations | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Alias | extensions, user content | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.property.modifierExtension | |||
| Short | Extensions that cannot be ignored even if unrecognized | ||
| Definition | May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). | ||
| Cardinality | 0..* | ||
| Type | Extension | ||
| Modifier | True | ||
| Summary | True | ||
| Alias | extensions, user content, modifiers | ||
| Requirements | Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. | ||
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.property.type | |||
| Short | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | ||
| Definition | Code that specifies the property DeviceDefinitionPropetyCode (Extensible). | ||
| Cardinality | 1..1 | ||
| Type | CodeableConcept | ||
| Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.property.valueQuantity | |||
| Short | Property value as a quantity | ||
| Definition | Property value as a quantity. | ||
| Cardinality | 0..* | ||
| Type | Quantity | ||
| Comments | The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.property.valueCode | |||
| Short | Property value as a code, e.g., NTP4 (synced to NTP) | ||
| Definition | Property value as a code, e.g., NTP4 (synced to NTP). | ||
| Cardinality | 0..* | ||
| Type | CodeableConcept | ||
| Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.patient | |||
| Short | Patient to whom Device is affixed | ||
| Definition | Patient information, If the device is affixed to a person. | ||
| Cardinality | 0..1 | ||
| Type | Reference(Patient) | ||
| Requirements | If the device is implanted in a patient, then need to associate the device to the patient. | ||
| Comments | References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.owner | |||
| Short | Organization responsible for device | ||
| Definition | An organization that is responsible for the provision and ongoing maintenance of the device. | ||
| Cardinality | 0..1 | ||
| Type | Reference(Organization) | ||
| Comments | References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.contact | |||
| Short | Details for human/organization for support | ||
| Definition | Contact details for an organization or a particular human that is responsible for the device. | ||
| Cardinality | 0..* | ||
| Type | ContactPoint | ||
| Comments | used for troubleshooting etc. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.location | |||
| Short | Where the device is found | ||
| Definition | The place where the device can be found. | ||
| Cardinality | 0..1 | ||
| Type | Reference(Location) | ||
| Requirements | Device.location can be used to track device location. | ||
| Comments | References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.url | |||
| Short | Network address to contact device | ||
| Definition | A network address on which the device may be contacted directly. | ||
| Cardinality | 0..1 | ||
| Type | uri | ||
| Comments | If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.note | |||
| Short | Device notes and comments | ||
| Definition | Descriptive information, usage information or implantation information that is not captured in an existing element. | ||
| Cardinality | 0..* | ||
| Type | Annotation | ||
| Comments | For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible). | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.safety | |||
| Short | Safety Characteristics of Device | ||
| Definition | Provides additional safety characteristics about a medical device. For example devices containing latex. | ||
| Cardinality | 0..* | ||
| Type | CodeableConcept | ||
| Summary | True | ||
| Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
| Device.parent | |||
| Short | The parent device | ||
| Definition | The parent device. | ||
| Cardinality | 0..1 | ||
| Type | Reference(Device) | ||
| Comments | References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. | ||
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | ||
| Constraints |
| ||
| Mappings |
| ||
XML View
JSON View
Examples
| id | div |
|---|---|
| UKCore-Device-BloodPressure-Sphygmomanometer-Example | An example to illustrate recording a specific blood pressure device |
UK Core Extensions examples can be found on the relevant Extension page.
Feedback
Click here to:Example Usage Scenarios
The following are example usage scenarios for the UK Core Device for Blood Pressure profile:
- Retrieve information pertaining to a blood pressure monitoring/recording device through querying.
- Record or update the device used to measure a patient's blood pressure
Profile Specific Implementation Guidance:
This is a derived profile of UKCore-Device (draft) and this page only shows the differences between the two. Refer to the base Profile for more implementation guidance.
Mandatory and Must Support Data Elements
The following elements are identified as MustSupport, and it is expected that consumers and suppliers SHALL support these as per the MustSupport Guidance.
| Element | Reason |
|---|---|
Device.status |
The status of the Device. |
Device.type |
The type of the Device. |
Extensions
More information about the extensions on the profile can be found using the links below.
| Extension | Context | Link | Comment |
|---|---|---|---|
| cuffSize | Device.extension | https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize | A code representing the cuff size of a sphygmomanometer. |
Bindings (differential)
More information about the bindings to UK Core ValueSets can be found below.
| Context | Strength | Link |
|---|---|---|
| Device.type | preferred | https://fhir.hl7.org.uk/ValueSet/UKCore-BloodPressureDeviceType |
| Device.extension:cuffSize | Preferred | ValueSet-UKCore-BloodPressure-CuffSize |
patient
Where possible, it is expected that the resource being referenced SHOULD conform to UKCore-Patient.
owner
Where possible, it is expected that the resource being referenced SHOULD conform to UKCore-Organization.
location
Where possible, it is expected that the resource being referenced SHOULD conform to UKCore-Location.
parent
Where possible, it is expected that the resource being referenced SHOULD conform to UKCore-Device (draft).