patientA reference to the patient who either received or did not receive the immunisation. The resource being referenced should conform to Profile UKCore-Patient.
| Immunization.id[0] | UKCore-Immunization-Sn-PatientConformVaccination-Example |
| Immunization.status[0] | completed |
| Immunization.vaccineCode[0].coding[0].system[0] | https://dmd.nhs.uk |
| Immunization.vaccineCode[0].coding[0].code[0] | 39114911000001105 |
| Immunization.vaccineCode[0].coding[0].display[0] | COVID-19 Vaccine Vaxzevria (ChAdOx1 S [recombinant]) not less than 2.5x100,000,000 infectious units/0.5ml dose suspension for injection multidose vials (AstraZeneca UK Ltd) |
| Immunization.patient[0].reference[0] | Patient/UKCore-Patient-RichardSmith-Example |
| Immunization.patient[0].type[0] | Patient |
| Immunization.patient[0].identifier[0].system[0] | https://fhir.nhs.uk/Id/nhs-number |
| Immunization.patient[0].identifier[0].value[0] | 9912003888 |
| Immunization.occurrenceDateTime[0] | 2021-07-20 |
| Immunization |
| id : UKCore-Immunization-Sn-PatientConformVaccination-Example |
| status : completed |
| vaccineCode |
| coding |
| system : https://dmd.nhs.uk |
| code : 39114911000001105 |
| display : COVID-19 Vaccine Vaxzevria (ChAdOx1 S [recombinant]) not less than 2.5x100,000,000 infectious units/0.5ml dose suspension for injection multidose vials (AstraZeneca UK Ltd) |
| patient |
| reference : Patient/UKCore-Patient-RichardSmith-Example |
| type : Patient |
| identifier |
| system : https://fhir.nhs.uk/Id/nhs-number |
| value : 9912003888 |
| occurrence : 2021-07-20 |
<Immunization xmlns="http://hl7.org/fhir"> <id value="UKCore-Immunization-Sn-PatientConformVaccination-Example" /> <status value="completed" /> <vaccineCode> <coding> <system value="https://dmd.nhs.uk" /> <code value="39114911000001105" /> <display value="COVID-19 Vaccine Vaxzevria (ChAdOx1 S [recombinant]) not less than 2.5x100,000,000 infectious units/0.5ml dose suspension for injection multidose vials (AstraZeneca UK Ltd)" /> </coding> </vaccineCode> <!-- **************snippet start************** --> <patient> <reference value="Patient/UKCore-Patient-RichardSmith-Example" /> <type value="Patient" /> <identifier> <system value="https://fhir.nhs.uk/Id/nhs-number" /> <value value="9912003888" /> </identifier> </patient> <!-- **************snippet end************** --> <occurrenceDateTime value="2021-07-20" /> </Immunization>
{ "resourceType": "Immunization", "id": "UKCore-Immunization-Sn-PatientConformVaccination-Example", "status": "completed", "vaccineCode": { "coding": [ { "system": "https://dmd.nhs.uk", "code": "39114911000001105", "display": "COVID-19 Vaccine Vaxzevria (ChAdOx1 S [recombinant]) not less than 2.5x100,000,000 infectious units/0.5ml dose suspension for injection multidose vials (AstraZeneca UK Ltd)" } ] }, "patient": { "reference": "Patient/UKCore-Patient-RichardSmith-Example", "type": "Patient", "identifier": { "system": "https://fhir.nhs.uk/Id/nhs-number", "value": "9912003888" } }, "occurrenceDateTime": "2021-07-20" }
Provider systems SHALL provide a reference and/or identifier that allows the consumer system to query another API if they need to access the complete UKCore-Patient resource.
Consumer systems SHALL consume this data.